The new closed cup flash point, designed by our team of engineers, integrates more than 20 years of experience with previous models. Flash point testers clarkson laboratory and supply inc. These test methods cover the determination of the flash point of petroleum products in the temperature range from 40 c to 370 c by a manual penskymartens closedcup apparatus or an automated penskymartens closedcup apparatus, and the determination of the flash point of biodiesel in the temperature range of 60 c to 190 c by an automated penskymartens closed cup apparatus. Flash point tester automated abel flash point tester. The system software runs on an integrated processor pc running the latest windows operating system. Its development in 1870 was for flash points well above 100 c to test lubricating oils and other similar products such as bitumen products. Consult anton paars entire pma 5 penskymartens flash point tester catalogue on directindustry. Integrated dual fan system directly cools test cup and surrounding environment. The sample is heated and stirred at specified rates depending on the material that is being tested. Penskymartens flash point tester fpm ducom instruments. Pensky marten flash point apparatus at rs 8160piece pensky. Mounts in base of penskymartens tester slow speed gear motor with twin pulley rotates stirrer of penskymartens closed cup flash tester at 115 rpm for the basic procedure or at 250 rpm for suspensions of solids and highly viscous samples. Petroleum products flash point by pensky martens apparatus. Product description the koehler k7 automatic pensky martens closed cup flash point analyzer is for flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film during testing.
Astm d92, iso 2592, jis k22654, ip 36, aashto t48, ftm 7911103, gost 4333 the best flash point tester for every task. This will be detected and signaled, preventing an accident or damage. Since a flash point of residual alcohol in biodiesel is difficult to observe by manual flash point techniques, automated apparatus with electronic flash point detection have been found suitable. Note 1flash point determination as above 250c can be performed. There are substances which do not have a flash point in a closed cup. In order to ensure safe operation of the apm7 flash point tester, this manual makes use of warnings and caution messages such as those below. The penskymartens flash point tester was developed in germany in 1870 by mr.
Pensky marten flash point apparatus is designed as per is 12091978. Pensky npm 440 automatic martens flash point apparatus by gecil process. Automatic pensky martens closed cup flash point analyzer 110240v 5060hz koehler k7 the automated pensky martens flash point analyzer represents a perfect union of nextgeneration technology with traditional robust quality. The automatic closed cup flash point tester autoflash93 detects the flash point. The apparatus required for this test is i penskymartens apparatus ii thermometer low range. The apparatus is widely used for determination for closed cup flash point of fuel oil, cut back asphalts, other viscous material and suspension of solids having a flash point above 49oc 120 of. Pensky martens flash point apparatus with voltage varic with geared electric motor stirrer 120 r. Wear niosh approved selfcontained breathing apparatus for confined spaces. Koehler instrument flash point cup for penskymartens closed. Flash point by penskymartens closed cup tester labequip.
The higher flash point temperature is always desirable. Flashpoint with closed cup penskymartens method pma 4. For flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing. Mar, 2020 according to astm d9319, penskymartens test procedures can determine the flash point of petroleum products in the 40c to 370c range by either manual or automated closedcup apparatus, as well as determining the flash point of biodiesel in the 60c to 190c range by an automated closedcup apparatus. Basics of penskymartens closedcup flash point testing. The flash point of a volatile material is the lowest temperature at which it can vaporise to form an ignitable mixture in air. Improper use andor negligence may result in serious personal injury or. According to astm d9319, pensky martens test procedures can determine the flash point of petroleum products in the 40c to 370c range by either manual or automated closedcup apparatus, as well as determining the flash point of biodiesel in the 60c to 190c range by an automated closedcup apparatus. Since 20 astm d7094 has been accepted in astm fuel specifications. Note 1 flash point determination as above 250c can be performed, however, the precisions have not been determined above this temperature. Manufacturer of flash point tester automatic pmcc flash point tester, pensky martens flash point apparatus semiautomatic offered by hindustan apparatus mfg.
Color coordinated display for high visibility and intuitive operation. The methods cover the determination of the flash point of petroleum products in the temperature range from 40 to 370c, and of biodiesel by an automated penskymartens closed cup apparatus in the temperature range of 60 to 190c. The pensky marten flash point apparatus is made as per ip 34. A brass test cup is filled with a test specimen and closed with a lid, through which an ignition source can be introduced periodically.
We are having different types of flash point apparatus used for different oils. Automated penskymartens closed cup flash point tester apm8fc. The eraflash flash point tester series uses the continuously closed cup flash point standards astm d6450, astm d7094 and ip 620. The automatic pensky martens closedcup tester measures the flash point at the lowest temperature at which the application of an ignition source causes the vapors of a sample to ignite. Pacs herzog optiflash is the new benchmark in flash point analysis, fully designed to meet. Basics of penskymartens closedcup flash point testing anton. Pma 5 penskymartens flash point tester anton paar pdf. Chuck accepts flexible stirrer shaft of flash tester. Koehler k7 penskymartens closedcup flash point tester. In this study, the flash points and fire points were measured to present raw data of the flammable risk assessment for acids, using pensky martens closed cupc. Standard test methods for flash point by penskymartens. Astm d93 standard test methods for flash point of petroleum products by penskymartens closed cup tester.
Accurate determination of vapor pressure of both automotive and aviation gasoline. Pensky npm 440 automatic flash point automatic martens. The automatic penskymartens closedcup tester measures the flash point at the lowest temperature at which the application of an ignition source causes. Astm d93 flash point tests by penskymartens closed cup. To avoid personal injury andor equipment damage, strictly observe these important safety precautions at all times. Ordering information hfp 339 pensky martens flash point analyzer is a compact and selfcontained instrument for precise flash point determination. This apparatus is used for determination of flash point and fire point of petroleum products open cup flash above 80c as per specification ip 36 and is. Fire point the fire point is the lowest temperature at which the application of test flame causes the material to ignite and burn at least for 5 seconds under specified conditions of the test. Astm d9318 standard test methods for flash point by pensky. Flash point by automatic penskymartens closed tester. Koehler instrument flash point cup for pensky martens closed tester flash point test cup spectrophotometers, refractometers and benchtop instruments. The flash point of any oil is defined as the lowest temperature at which it forms vapors and produces combustible mixture with air. Flash point apparatus pensky marten flash point apparatus. Above the flash point explosive vaporair mixtures may be formed.
Flash point apparatus pensky martin flash point apparatus. The semiautomatic penskymartens closed cup tester measures the flash point at the lowest temperature at which the application of an ignition source causes. Astm d93, iso 2719, ip 34 cleveland opencup flash and fire point tester. Note 1flash point determination as above 250c can be performed, however, the precisions have not been determined above this temperature. Automatic pensky martens closed cup flash point analyzer 110240v 5060hz koehler k7 for international destinations automatic tag closed cup flash point tester 115v. Flash point tester automatic pmcc flash point tester. Pdf a study on flash points and fire points of acids using. A round robin test by astm showed no statistical bias, proving that astm d7094 and the d93 pensky martens method are interchangeable.
The pensky martens test is a closedcup method as opposed to the cleveland opencup method. Penskymartens closed cup automatic flash point tester model. Pensky martens tag abel choice of configurations semiautomatic or manual operation 230 or 115 vac gas ignition optional bath cooling accuracyenhancing flash alert available semiautomatic and manual flash point testers hfp 380 series d esigned to provide years of accurate and reliable flash point results, herzogs top. The apparatus consists of a cup, heating plate to spectificdimension thermometer clip and test flame attachment with swivel joint for passing over test liquid surface in the prescribed manner, heating is controlled by means. Petroleum products we are a leading manufacturer of flash point by pensky martens apparatus, smoke point apparatus, bulk density apparatus, softening point apparatus, penetrometer and anline point apparatus from coimbatore, india. Included is a user friendly manual machine interface, electric standard or gas optional ignition and thermal detection. Originally established in 1931, herzog has a comprehensive line of laboratory instruments for testing atmospheric and vacuum distillation, flash point, vapor pressure, bitumen properties, cold flow properties, viscosity and other physical properties of materials.
Petroleum products and lubricants determination of flash point by the pensky martens closed cup method. Its development in 1870 was for flash points well above 100 c to test lubricating oils and other similar. The automated pensky martens flash point analyzer represents a perfect union of nextgeneration technology with traditional robust quality. Martens and was based on the original tester by mr. Pma 5 is suitable for flammability applications on both biodiesel and biodieselblended fuels along with distillate fuels like diesel, heating oil, and kerosene. Auto penskymartens closed cup flash point tester conforms to astm d93 and related specifications dual flash point detection system thermal and ionization for measurement of samples containing water andor silicone gas or electric ignition flash point operation range between 0 and 400c simple automation routine for easy. Astm d 9308 test method for flash point by penskymartens.